Introduction

This document is provided to assist in removing and replacing the power supply for the HP xw4600 Workstation.

top

Minimum skill level

No hardware-specific training is required.

top

Tools required

Torx-15 screw driver

top

Parts required

NOTE: Part numbers are subject to change.

The replacement part number will vary depending on the power supply that is being replaced. If a part is listed as "Yes" under "Requires Return" then the defective part needs to be returned to HP. Click here for more information on returning parts to HP .

Description
Part Number
Requires Return
Power supply, 475 Watt
452554-001 (Modified)
Yes
NOTE: For customers in countries/regions with RoHS legislation* (e.g. EU, China, etc.) restricting the use of hazardous substances in electrical equipment. The use of the Original Spare part is regulated by RoHS legislation. If your unit contains a part that is labelled with the Modified Spare number, the Modified Spare must be ordered as the replacement part. If your unit contains a part that is labelled with the Original Spare number, please order the Original Spare as the replacement part. In this case either the Original Spare or the Modified Spare may be shipped which will not affect performance or functionality of the unit.

top

Summary of instructions

To view a video demonstrating the procedure for removing the power supply, click on the link below. Or use the product video listing on the HP Services Media Library , then select Power supply from the menu on the upper left hand side of the screen.

Click here to view the power supply removal video (right-click on the link to open in a new window/tab).

Power supply removal

  1. Review the safety considerations before performing the steps listed below by clicking on the following link:

    Click here to view the precautions .

    CAUTION: Failure to comply with the precautions could result in damage to your product or loss of data.
    NOTE: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.
  2. Power down the workstation and remove the power cord from the electrical outlet.

  3. Remove the access panel. Click here for instructions on removing the access panel .

  4. Disconnect the power cables from all of the drives and the system board, noting their location for reinstallation.

  5. Remove the four Torx-15 screws that secure the power supply to the back of the chassis.

  6. Slide the power supply away from the back of the chassis.

  7. Lift the power supply and remove it from the chassis.

Power supply replacement

  1. Place the power supply into the chassis.

  2. Slide the power supply into place against the back of the chassis.

  3. Replace the four Torx-15 screws that secure the power supply to the back of the chassis.

  4. Connect the power cables to the drives and system board.

  5. Replace the access panel. Click here for instructions on replacing the access panel .

top

Parts return

If your part requires return then click on the appropriate link below:

Click here for the defective parts return procedure for US .

Click here for the defective parts return procedure for Europe .

top